Glass Thickness Calculation with PROJECTVITRUM
Choose the intended use
- Step
- Walkable surface
- Roof
- Partitions and Windows
- Parapets
Choose the type of step
- Step on 4 sides
- Step on 3 sides
- Step on 2 sides
- Elementi Sagomati
Choose the type of walkable surface
- Surface with 4-side support
- Surface with 3-side support
- Surface with 2-side support
- Elementi Sagomati
Choose the type of roof
- Roof/Canopy with 4-side support
- Roof/Canopy with 3-side support
- Roof/Canopy with 2-side support
- Elementi Sagomati
Choose the type of wall / window
- Partitions and windows fixed on 4 sides
- Partitions and windows fixed on 3 sides
- Partitions and windows fixed on 2 sides
- Elementi Sagomati
Choose the type of parapet
- Parapet recess-fixed at the base
Chose the installation area
- Indoor area
- Outdoor uncovered or sheltered area
Select the type of wall to be sized
- Windows and partitions subjected to external loads
- Movable Walls - Internal Partitions
Choose whether you prefer to do the dimensioning based on safety and performance or ONLY on safety
- Guarantee safety and performance
- Garantee ONLY safety
Choose the type of fixing
Floor RECESS FIXING:
zero clearance
70mm min
Top HINGE:
with clearance
20mm min
Floor HINGE:
with clearance
20mm min
Top HINGE:
with clearance
20mm min
Floor RECESS FIXING:
zero clearance
70mm min
Top RECESS FIXING:
zero clearance
70mm min
Select the Calculation Option the program should use to size the parapets
- Calculation done as per CNR DT210:2013
- Calculation done under
CPR 305/2011
Choose the system that best meets your requirements
- Generic
floor fixing - Generic
side fixing
- Floor fixing
(DEFENDER LM) - Floor fixing on one side
(DEFENDER MS)
- Floor fixing
with side foot
(DEFENDER DK)
- Side fixing
(DEFENDER FR) - Side fixing
with foot at the base
(DEFENDER SP)
- Small floor fixing
(DEFENDER XP) - Small floor fixing on one side
(DEFENDER pico)
- SABCO
floor fixing - SABCO
side fixing
- SABCO
floor fixing - SABCO
floor fixing
Enter the dimensions in [mm]
In order to continue, you need to select the type of support
Side 1 | Side 1 | |||
500 mm | 500 mm | |||
- + |
- + |
Wall H. | Upper H. | 0 mm | ||
- + |
- + |
Is the partition/window exposed to human impact load?
No
Yes
Is the upper edge of the partition / window under 6m from the street level?
No
Yes
Does the roof/canopy need accessibility for maintenance?
No
Yes
Select the place of installation
Region | |
Province | |
Municipality | |
Altitude | |
Topography | |
Roughness Category | |
Distance from the sea | |
Watertight structure |
-
+
Uniformly Distributed Load
-
+
Load time
-
+
Operating Temperature
 
Operating Temperature
 
 
-
+
Choose the laminating plastic
Plastics considered <>
Characterized plastics
Plastics not characterized
Composite interlayer
Use polymers with an Avis Tecnique to be used in safety glass
Edge finish quality
Rough polished
Shiny ground
Non-slip glass
NO
of generic type
YES: Madras 8mm
YES: Madras 10mm

Madras - Ecosat Flooring

Madras - Grid XP Flooring

Madras - Matrix Flooring

Madras - Pixel Flooring
Consequence class
ULS or LSC
ULTIMATE Limit State (ULS)
+
SERVICEABILITY Limit State(sLS)
+
SERVICEABILITY Limit State(sLS)
COLLAPSE Limit State (CLS)
according to CNR DT210
Calculation in progress ...